Standards
- ISO 6722, ISO 14572: International standards for automotive cables and electrical continuity.
- IEC 60529: IP code compliance for dust/water resistance during high-voltage testing.
- UL 2556: Wire and cable test methods for safety certification.
- GB/T 18384: China’s national standard for electric vehicle safety requirements.
- Equivalent Standards: SAE J1678, LV 123 (automotive OEM specifications).
Main Parameters:
1. Power: 3KVA
2. Input voltage: 220V/50HZ
3. Voltage output: AC/DC: 0 - 10KV or 0 - 15KV
4. Breakdown current: 0 - 300 mA or 0 - 500 mA
5. Test time: Can be set within the range of 1 - 999.9 S/M/H
6. Voltage - rising mode: It has an electric control function and can automatically raise the voltage to the set value according to the preset voltage value.
7. Voltage - rising speed: Can be set within the range of 10V - 500V/S
8. Alarm functions: Threshold safety alarm, zero - voltage safety alarm, audible and visual alarm during voltage - rising, breakdown alarm
9. Emergency stop function: Equipped with an emergency stop function, which can quickly cut off the voltage and terminate the test.
10. Transformer protection function: When the transformer is over - current or over - loaded, it can automatically cut off the test input voltage, terminate the test, and protect the transformer.