The Nonwovens Liquid Loss Tester is a precision instrument designed to evaluate the liquid penetration, slip, and loss performance of nonwoven fabric materials. It features a built-in liquid loss platform and sample fixture, enabling standardized testing of absorption and liquid retention characteristics, suitable for both R&D and production quality control.
Application
The tester is widely applicable across multiple industries:
(1) Hygiene products: diapers, adult incontinence products, sanitary pads
(2) Medical textiles: wound dressings, surgical gowns, masks
(3) Filtration materials: air filters, water filters, industrial wipes
(4) Food packaging: absorbent pads, protective liners
(5) Industrial absorbents: oil-absorbing mats, chemical spill pads
(6) Textiles and nonwoven R&D: evaluating new materials, coatings, and treatments
(7) Quality control laboratories: production batch testing, compliance verification
(8) Building and construction: moisture barrier textiles, insulation fabrics
(9) Automotive: cabin filters, absorbent mats, soundproofing layers
(10) Environmental engineering: spill control fabrics, eco-friendly absorbents
Standards
EDANA 152.0-99 (Absorbent Hygiene Products – Liquid Loss Test)
ISO 9073-11 (Textiles – Nonwovens – Determination of Liquid Loss)
Optional references for hygiene products: ASTM F2331, EN 13726-1
Features
(1) Equipped with standardized liquid loss platform and sample fixture to meet test requirements
(2) Integrated dosing device delivers 25 mL of test solution continuously within 4 ± 0.1 seconds
(3) Manual or automatic liquid dispensing, with digital display for accurate timing
(4) Optional weighing system to measure liquid absorption quantitatively
(5) Adjustable slope for controlled liquid flow over the sample
(6) High precision and repeatability for reliable quality control results
Test Principle
A standard absorbent medium is placed beneath the nonwoven sample, positioned on a sloping pad. A specified amount of test liquid is applied to the sample. The liquid penetrates the nonwoven and is absorbed by the medium. By measuring the mass of the absorbent medium before and after testing, the liquid loss performance of the nonwoven sample is calculated.
Technical Parameters
| Parameter | Specification |
|---|---|
| Flow Control Range | 6.10–6.41 mL/s |
| Slope Angle | 25° |
| Slip and Loss Length | 250 ± 0.2 mm |
| Timing | 60 s, ±0.1 s accuracy |
| Slip and Loss Weight | 30 g ± 0.01 g |
| Liquid Volume | 25 mL/test |
| Measurement Method | Gravimetric via absorbent medium |